Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
2.
Eye (Lond) ; 33(3): 469-477, 2019 03.
Article in English | MEDLINE | ID: mdl-30356133

ABSTRACT

AIMS: To assess the efficacy of Xen in reducing intraocular pressure (IOP) in varying glaucoma subtypes. To assess the effect of combined phacoemulsification. To determine the frequency of complications and explore further bleb management needed. METHODS: Retrospective case note review of all patients undergoing Xen implantation across four centres from August 2015 to May 2017. RESULTS: In total, 259 consecutive surgeries of 226 patients were reviewed. IOP reduced from 19.3 (SD ± 6.0) mmHg preoperatively to 14.2 (SD ± 4.4) at month 12 and 13.5 (SD ± 3.3) at month 18 (p < 0.0001). Medication usage reduced from 2.6 (±1.1) preoperatively to 0.8 (±1.0) at month 12 (p < 0.0001) and 1.1 (±1.3) medications at month 18 (p < 0.0001). Simultaneous phacoemulsification did not alter outcomes as Xen IOP was 14.3 (SD ± 4.7) mmHg and Phaco-Xen was 13.8 (SD ± 2.6) mmHg at month 12 (p = 0.5367). Xen appears to be effective in previous failed filtration surgery. Adverse events included: IOP spikes of ≥30 mmHg in 33 (12.7%) cases, secondary filtration surgery required in 24 (9.3%) cases; implant exposure in 6 (2.3%) cases; persistent hypotonous maculopathy in 5 (1.9%) cases; persistent choroidal effusions in 4 (1.5%) cases; a cyclodialysis cleft secondary to implant insertion in 1 (0.5%) case; and 1 (0.5%) case of endophthalmitis post-implant bleb resuturing. In all, 40.9% of cases required postoperative bleb needling or antimetabolite injection. CONCLUSIONS: Xen reduces IOP and medications at 18 months. Adverse events are uncommon. Careful postoperative surveillance and low threshold for bleb management is needed. Xen is safe and effective in mild to moderate glaucoma.


Subject(s)
Cataract Extraction/methods , Glaucoma Drainage Implants , Glaucoma/surgery , Intraocular Pressure/physiology , Lens Implantation, Intraocular/methods , Stents , Adult , Aged , Aged, 80 and over , Female , Glaucoma/physiopathology , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures , Prosthesis Design , Retrospective Studies , Trabeculectomy , Treatment Outcome , Visual Acuity
3.
BMC Ophthalmol ; 17(1): 264, 2017 Dec 28.
Article in English | MEDLINE | ID: mdl-29282030

ABSTRACT

BACKGROUND: Silicone oil tamponade is more frequently reserved for cases of complex retinal detachment. We describe the effects of different variations in oil ratios with the relatively unknown technique of double oil tamponade. METHODS: Retrospective case note review of nine patients with complex rhegmatogenous retinal detachment (RD). All cases had both superior and inferior breaks, mostly with associated proliferative vitreoretinopathy (PVR). All cases were treated with pars plana vitrectomy (PPV) and a double silicone oil endotamponade (DSOE) of both heavy silicone oil and conventional 'light' silicone oil. Ratios were varied to suit different RD configurations. In vitro observations were studied to help direct these decisions. RESULTS: Anatomical success was achieved in all cases. Common complications were the same as those seen in single oil tamponade (elevated intraocular pressure, cystoid macular oedema (CMO), cataract and posterior capsule opacification. No single case of recurrent RD was seen whilst mixed oil remained in situ. CONCLUSIONS: Double silicone oil endotamponade is a safe and effective treatment for complex retinal detachments with superior and inferior breaks. Differences in oil ratios can be tailored to best fit the distribution of retinal pathology. In vitro observations may help to inform these choices.


Subject(s)
Endotamponade/methods , Retinal Detachment/surgery , Silicone Oils/pharmacology , Visual Acuity , Vitrectomy/methods , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Retinal Detachment/physiopathology , Retrospective Studies , Treatment Outcome
4.
Oman J Ophthalmol ; 8(3): 213-4, 2015.
Article in English | MEDLINE | ID: mdl-26903737

ABSTRACT

Subhyaloid hemorrhages can occur as a result of exposure to high altitude. We hereby report a clinical picture of subhyaloid hemorrhage associated with high altitude. The case demonstrates optical coherence tomography findings that aid diagnosis of subhyaloid hemorrhage.

5.
J Vis Exp ; (47)2011 Jan 16.
Article in English | MEDLINE | ID: mdl-21304456

ABSTRACT

UNLABELLED: PART 1: PURPOSE: To demonstrate a capsulorhexis radial tear out rescue technique using a cystotome on a virtual reality cataract surgery simulator and in a human eye. PART 2: METHOD: Steps: When a capsulorhexis begins to veer radially towards the periphery beyond the pupillary margin the following steps should be applied without delay. 2.1) Stop further capsulorhexis manoeuvre and reassess the situation. 2.2) Fill the anterior chamber with ophthalmic viscosurgical device (OVD). We recommend mounting the cystotome to a syringe containing OVD so that the anterior chamber can be reinflated rapidly. 2.3) The capsulorhexis flap is then left unfolded on the lens surface. 2.4) The cystotome tip is tilted horizontally to avoid cutting or puncturing the flap and is engaged on the flap near the leading edge of the tear but not too close to the point of tear. 2.5) Gently push or pull the leading edge of tear opposite to the direction of tear. 2.6) The leading tearing edge will start to do a 'U-Turn'. Maintain the tension on the flap until the tearing edge returns to the desired trajectory. PART 3: RESULTS: Using our technique, a surgeon can respond instantly to radial tear out without having to change surgical instruments. Changing surgical instruments at this critical stage runs a risk of further radial tear due to sudden shallowing of anterior chamber as a result of forward pressure from the vitreous. Our technique also has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. PART 4: DISCUSSION: The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis tear-out techniques. Capsulorhexis is the most important and complex part of phacoemulsification and endocapsular intraocular lens implantation procedure. A successful cataract surgery depends on achieving a good capsulorhexis. During capsulorhexis, surgeons may face a challenging situation like a capsulorhexis radial tear-out. A surgeon must learn to tackle the problem promptly without making the situation worse. Some other methods of rescuing the situation have been described using a capsulorhexis forceps. However, we believe our method is quicker, more effective and easier to manipulate as demonstrated on the EYESi surgical simulator and on a human eye.


Subject(s)
Capsulorhexis/methods , User-Computer Interface , Anterior Chamber/surgery , Capsulorhexis/education , Computer Simulation , Humans , Lens Capsule, Crystalline/surgery , Ophthalmic Solutions/administration & dosage , Viscoelastic Substances/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...